Victron Cyrix-Li-charger 24/48V 120A load disconnect for Victron Smart LiFePO4 Batteries
Accompanying
Documents:
PRICE PER UNIT
Courier (ACS / ELTA): Delivery in 1-3 working days
BoxNow Locker: Pickup from 1,200+ points
Transport company: For bulky & fragile products (e.g. PV panels)
International shipping
Product Description
Victron Cyrix-Li-charge 24/48V 120A charger disconnect for Victron Smart LiFePO4 Batteries
Victron Cyrix-Li battery protection system for Smart Victron LiFePO4 batteries
Same as all other Cyrix-Li Victron battery protection devices, Cyrix-Li-ct is only compatible with Victron LiFePO4 Smart batteries.
The use of a Victron VE.Bus BMS like the: Victron VE.Bus BMS V2
The LiFePO4 battery: preventing cell under voltage, over voltage and over temperature
The first line of protection is cell balancing. All Victron LiFePO4 batteries have integrated cell balancing.
The second line of protection consists of:
– shut down of the load in case of imminent cell under voltage, and
– shut down or reduction of the charging current in case of imminent cell over voltage, high temperature (>50°C) or
low temperature (<0°C).
The VE.Bus BMS is the core of the second protection line.
However, not all loads or chargers can be controlled directly by the VE.Bus BMS.
In order to shut down such loads or chargers several VE.Bus BMS controllable Cyrix switches are available.
Victron Cyrix-Li-charge 24/48V 120A charge disconnect for Victron Smart LiFePO4 Batteries
The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:
– if the charge disconnect output of the VE.Bus BMS is high, and
– if it senses 13,0 V (resp. 26,0 V or 52,0 V) or more on its battery charger connection terminal, and
– if it senses 2 V or more on its battery terminal
(the Cyrix will remain open if not connect to the battery).
The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over
temperature.
In general, a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3
seconds
When the Cyrix-Li-Charge is engaged (charger connected to battery) it will disengage after 1 hour to check if the charger is still enabled..
If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13,0 V or more, the Cyrix will reengage, with a 3
seconds delay.
Note: In case of zero discharge current, or a small discharge current, the Cyrix will not disengage shortly after the charger has been switched off
and/or disconnected, because battery voltage will remain higher than 13,5 V.
Made in the Netherlands.
2-Year Warranty
Technical Specifications
-
ManufacturerVictron
Product Description
Victron Cyrix-Li-charge 24/48V 120A charger disconnect for Victron Smart LiFePO4 Batteries
Victron Cyrix-Li battery protection system for Smart Victron LiFePO4 batteries
Same as all other Cyrix-Li Victron battery protection devices, Cyrix-Li-ct is only compatible with Victron LiFePO4 Smart batteries.
The use of a Victron VE.Bus BMS like the: Victron VE.Bus BMS V2
The LiFePO4 battery: preventing cell under voltage, over voltage and over temperature
The first line of protection is cell balancing. All Victron LiFePO4 batteries have integrated cell balancing.
The second line of protection consists of:
– shut down of the load in case of imminent cell under voltage, and
– shut down or reduction of the charging current in case of imminent cell over voltage, high temperature (>50°C) or
low temperature (<0°C).
The VE.Bus BMS is the core of the second protection line.
However, not all loads or chargers can be controlled directly by the VE.Bus BMS.
In order to shut down such loads or chargers several VE.Bus BMS controllable Cyrix switches are available.
Victron Cyrix-Li-charge 24/48V 120A charge disconnect for Victron Smart LiFePO4 Batteries
The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:
– if the charge disconnect output of the VE.Bus BMS is high, and
– if it senses 13,0 V (resp. 26,0 V or 52,0 V) or more on its battery charger connection terminal, and
– if it senses 2 V or more on its battery terminal
(the Cyrix will remain open if not connect to the battery).
The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over
temperature.
In general, a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3
seconds
When the Cyrix-Li-Charge is engaged (charger connected to battery) it will disengage after 1 hour to check if the charger is still enabled..
If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13,0 V or more, the Cyrix will reengage, with a 3
seconds delay.
Note: In case of zero discharge current, or a small discharge current, the Cyrix will not disengage shortly after the charger has been switched off
and/or disconnected, because battery voltage will remain higher than 13,5 V.
Made in the Netherlands.
2-Year Warranty
Technical Specifications
-
ManufacturerVictron