Water Presence Monitoring Relay 230V AC Aqua Stop Plug-In Type
PRICE PER UNIT
Courier (ACS / ELTA): Delivery in 1-3 working days
BoxNow Locker: Pickup from 1,200+ points
Transport company: For bulky & fragile products (e.g. PV panels)
International shipping
Product Description
Water Presence Monitoring Relay 230V AC Aqua Stop Plug-In Type
Operating Description
The system operates when the motor grounding, through the pipe and the water,
closes the circuit with the electrode.
If the pipe between the pump and the electrode is plastic,
the electrode tee must be grounded. The electrode must be installed
in a suitable position so that, in case of water interruption, it does not remain wet,
while also avoiding air trapping.
Protection Time Delays
- Start-up delay: 2 minutes after each mains power interruption,
to ensure that water is present before start-up. - Stop delay: 4 seconds during shutdown,
to prevent momentary interruptions in operation.
Suitable Use
The device is suitable for direct motor connection up to 1.5 Hp.
Attention
During initial installation, if the electrode is not in contact with water, the device
operates for 4 seconds and then stops.
Technical Specifications
- Sensitivity: 10 kΩ
- Electrode voltage: 20V AC max
- Electrode current: 2mA max
- Transformer isolation: 4000V max
- Supply voltage: 230V ±10%
- Power consumption: 2VA max
- Maximum contact current: 30A AC1
Operating Indicators
The device features an integrated LED indicator, which shows relay activation.
Technical Specifications
-
ManufacturerCronos
Product Description
Water Presence Monitoring Relay 230V AC Aqua Stop Plug-In Type
Operating Description
The system operates when the motor grounding, through the pipe and the water,
closes the circuit with the electrode.
If the pipe between the pump and the electrode is plastic,
the electrode tee must be grounded. The electrode must be installed
in a suitable position so that, in case of water interruption, it does not remain wet,
while also avoiding air trapping.
Protection Time Delays
- Start-up delay: 2 minutes after each mains power interruption,
to ensure that water is present before start-up. - Stop delay: 4 seconds during shutdown,
to prevent momentary interruptions in operation.
Suitable Use
The device is suitable for direct motor connection up to 1.5 Hp.
Attention
During initial installation, if the electrode is not in contact with water, the device
operates for 4 seconds and then stops.
Technical Specifications
- Sensitivity: 10 kΩ
- Electrode voltage: 20V AC max
- Electrode current: 2mA max
- Transformer isolation: 4000V max
- Supply voltage: 230V ±10%
- Power consumption: 2VA max
- Maximum contact current: 30A AC1
Operating Indicators
The device features an integrated LED indicator, which shows relay activation.
Technical Specifications
-
ManufacturerCronos