Inverter/Charger w/ UPS Mode Victron Multiplus-II 12/5000/220-50 5000VA 12V from 220A AC charger
PRICE PER UNIT
Courier (ACS / ELTA): Delivery in 1-3 working days
BoxNow Locker: Pickup from 1,200+ points
Transport company: For bulky & fragile products (e.g. PV panels)
International shipping
Product Description
Inverter/Charger w/ UPS Mode Victron Multiplus-II 12/5000/220-50 5000VA 12V from 220A AC charger
Pure sine wave inverter/charger with integrated UPS function (transfer time <20 ms), ideal for boats, vehicles, and off-grid/ESS applications. It offers PowerControl and PowerAssist to prevent grid/generator overload, two AC outputs, and the ability to operate in parallel and three-phase configurations for virtually unlimited power.
- Rated Inverter Power: 5000 VA (continuous up to ~4000 W @ 25 °C) · peak up to ~9000 W.
- AC Output: 230 VAC ± 2% · 50 Hz (adjustable) · UPS transfer <20 ms for uninterrupted supply of critical loads.
- DC Input (battery): 12 V (range 9.5–17 V).
- Integrated AC Charger: max 220 A with adaptive 4-stage algorithm (Bulk/Absorption/Float/Storage). Charging voltages: 14.4 V (Abs), 13.8 V (Float), 13.2 V (Storage) · temperature sensor included.
- Transfer Switch / AC Input Current: built-in 50 A transfer switch and maximum AC input current of 50 A.
- Dual AC Outputs: AC-out-1 (no-break UPS output) & AC-out-2 disabled when running on battery (e.g. for water heater).
- PowerControl / PowerAssist: limits current draw from grid or generator and boosts load power from battery when needed.
- Parallel & Three-Phase Operation: supports up to 6 units in parallel and 3-phase configuration.
- ESS & PV Compatibility: for off-grid or grid-connected systems with solar charge controllers or inverters; optional external current sensor (50 A / 100 A) for optimized self-consumption.
- Efficiency & No-Load Consumption: high efficiency up to ~95–96% · typical no-load consumption ~15–18 W (AES / Search modes for further reduction).
- Communication & Monitoring: VE.Bus for integration and parallel operation; compatible with Cerbo GX / other GX devices & VRM portal for remote monitoring and configuration.
- Protections: output short circuit, overload, high/low battery voltage, over-temperature, input ripple, and more.
- Protection Rating & Environment: IP22 · operating temperature range −40 °C to +65 °C (with forced cooling).
Main Features
- True sine wave UPS mode for sensitive electronics and servers.
- Battery management with adaptive charging and temperature compensation; supports lead-acid and LiFePO4 (via BMS/settings).
- AC-out-2 for non-critical loads that should not discharge the battery.
- Configuration & control via VictronConnect / VEConfigure and optional Digital Multi Control panel.
Typical Applications
Boats and recreational vehicles, stand-alone systems, small hybrid ESS with solar PV, and backup power for critical loads in residential or commercial installations.
Installation Notes
- Install in a dry, well-ventilated area, as close to the battery as possible, with at least 10 cm clearance around the unit.
- To fully utilize the 12/5000/220 model, use an appropriately sized battery bank, correct DC cable sizing, and proper DC fuse as specified in the manual’s table.
Local Monitoring
Is performed via connection with a mobile phone or computer through:
*Victron VE.Bus Smart Dongle – Smart Cover or alternatively
*Victron Interface MK3-USB (VE.Bus to USB) or alternatively
*Victron Interface MK3-USB (VE.Bus to USB-C)Remote Monitoring
Is performed via internet connection through:
*Victron Cerbo GX MK2, which for its connection requires:
Victron RJ45 UTP Cable 1.8m
WARRANTY 5 YEARS
Technical Specifications
-
ManualsManual Victron MultiPlus-II 12/5000/220-50 5000VA 12V
-
ManufacturerVictron
-
Voltage (V)12V
-
Sine WavePure
-
Off-grid Inverter TypeInverter+charger+UPS mode
-
Parallel Capable1
-
Watt/VA5.000
Product Description
Inverter/Charger w/ UPS Mode Victron Multiplus-II 12/5000/220-50 5000VA 12V from 220A AC charger
Pure sine wave inverter/charger with integrated UPS function (transfer time <20 ms), ideal for boats, vehicles, and off-grid/ESS applications. It offers PowerControl and PowerAssist to prevent grid/generator overload, two AC outputs, and the ability to operate in parallel and three-phase configurations for virtually unlimited power.
- Rated Inverter Power: 5000 VA (continuous up to ~4000 W @ 25 °C) · peak up to ~9000 W.
- AC Output: 230 VAC ± 2% · 50 Hz (adjustable) · UPS transfer <20 ms for uninterrupted supply of critical loads.
- DC Input (battery): 12 V (range 9.5–17 V).
- Integrated AC Charger: max 220 A with adaptive 4-stage algorithm (Bulk/Absorption/Float/Storage). Charging voltages: 14.4 V (Abs), 13.8 V (Float), 13.2 V (Storage) · temperature sensor included.
- Transfer Switch / AC Input Current: built-in 50 A transfer switch and maximum AC input current of 50 A.
- Dual AC Outputs: AC-out-1 (no-break UPS output) & AC-out-2 disabled when running on battery (e.g. for water heater).
- PowerControl / PowerAssist: limits current draw from grid or generator and boosts load power from battery when needed.
- Parallel & Three-Phase Operation: supports up to 6 units in parallel and 3-phase configuration.
- ESS & PV Compatibility: for off-grid or grid-connected systems with solar charge controllers or inverters; optional external current sensor (50 A / 100 A) for optimized self-consumption.
- Efficiency & No-Load Consumption: high efficiency up to ~95–96% · typical no-load consumption ~15–18 W (AES / Search modes for further reduction).
- Communication & Monitoring: VE.Bus for integration and parallel operation; compatible with Cerbo GX / other GX devices & VRM portal for remote monitoring and configuration.
- Protections: output short circuit, overload, high/low battery voltage, over-temperature, input ripple, and more.
- Protection Rating & Environment: IP22 · operating temperature range −40 °C to +65 °C (with forced cooling).
Main Features
- True sine wave UPS mode for sensitive electronics and servers.
- Battery management with adaptive charging and temperature compensation; supports lead-acid and LiFePO4 (via BMS/settings).
- AC-out-2 for non-critical loads that should not discharge the battery.
- Configuration & control via VictronConnect / VEConfigure and optional Digital Multi Control panel.
Typical Applications
Boats and recreational vehicles, stand-alone systems, small hybrid ESS with solar PV, and backup power for critical loads in residential or commercial installations.
Installation Notes
- Install in a dry, well-ventilated area, as close to the battery as possible, with at least 10 cm clearance around the unit.
- To fully utilize the 12/5000/220 model, use an appropriately sized battery bank, correct DC cable sizing, and proper DC fuse as specified in the manual’s table.
Local Monitoring
Is performed via connection with a mobile phone or computer through:
*Victron VE.Bus Smart Dongle – Smart Cover or alternatively
*Victron Interface MK3-USB (VE.Bus to USB) or alternatively
*Victron Interface MK3-USB (VE.Bus to USB-C)Remote Monitoring
Is performed via internet connection through:
*Victron Cerbo GX MK2, which for its connection requires:
Victron RJ45 UTP Cable 1.8m
WARRANTY 5 YEARS
Technical Specifications
-
ManualsManual Victron MultiPlus-II 12/5000/220-50 5000VA 12V
-
ManufacturerVictron
-
Voltage (V)12V
-
Sine WavePure
-
Off-grid Inverter TypeInverter+charger+UPS mode
-
Parallel Capable1
-
Watt/VA5.000