Generator Automation RLG300
Generator Automation RLG300
Generator Automation. Receives a command from a grid monitor and starts the generator when it detects a fault.
Automatically transfers loads from the grid to the generator and vice versa when needed. The switching is done with an appropriate time delay to protect the relays. When the grid is restored, it puts out of service
the loads on the generator but keeps the motor running for 2.5 minutes which is sufficient time for cooling. Provides a LCD display for user monitoring and LED indicators of key functions for real-time updates. Can test for good motor operation while there are loads on the grid. In manual mode there is the capability to start the motor with the push button (START) and with the push switch - button (POWER TO LOAD) to make the switching of the loads.
Attention!: In manual mode it is not possible to monitor malfunctions.
Technical Characteristics:
- Power supply: 9V – 30V DC
- Consumption in the AUTO position at rest: 110mA
- Dimensions (WxHxD): 30 x 19.8 x 7.5 cm
- Mounting hole dimensions (WxH): 26.9 x 16.7 cm
- Weight: 900gr.
LED indicators: Ignition function, Valve function, Grid loads, Generator loads, Low oil pressure, Low fuel level.
LCD display indicators :
- Idle: Battery voltage, charging current
- During operation: Hours of operation
- At failure: Depicts which input caused a malfunction, then the screen flashes indicating that the operation of the board is locked and the siren rings. Reset is needed for the automation to work again.
Technical Specifications
-
ManufacturerCronos
Product Description
Generator Automation RLG300
Generator Automation RLG300
Generator Automation. Receives a command from a grid monitor and starts the generator when it detects a fault.
Automatically transfers loads from the grid to the generator and vice versa when needed. The switching is done with an appropriate time delay to protect the relays. When the grid is restored, it puts out of service
the loads on the generator but keeps the motor running for 2.5 minutes which is sufficient time for cooling. Provides a LCD display for user monitoring and LED indicators of key functions for real-time updates. Can test for good motor operation while there are loads on the grid. In manual mode there is the capability to start the motor with the push button (START) and with the push switch - button (POWER TO LOAD) to make the switching of the loads.
Attention!: In manual mode it is not possible to monitor malfunctions.
Technical Characteristics:
- Power supply: 9V – 30V DC
- Consumption in the AUTO position at rest: 110mA
- Dimensions (WxHxD): 30 x 19.8 x 7.5 cm
- Mounting hole dimensions (WxH): 26.9 x 16.7 cm
- Weight: 900gr.
LED indicators: Ignition function, Valve function, Grid loads, Generator loads, Low oil pressure, Low fuel level.
LCD display indicators :
- Idle: Battery voltage, charging current
- During operation: Hours of operation
- At failure: Depicts which input caused a malfunction, then the screen flashes indicating that the operation of the board is locked and the siren rings. Reset is needed for the automation to work again.
Technical Specifications
-
ManufacturerCronos