Constant Current Pulse Width Modulator PWM CCPWM60A 60A 12/24V for Hydrogen Systems
Accompanying
Documents:
PRICE PER UNIT
Courier (ACS / ELTA): Delivery in 1-3 working days
BoxNow Locker: Pickup from 1,200+ points
Transport company: For bulky & fragile products (e.g. PV panels)
International shipping
Product Description
Constant Current Pulse Width Modulator PWM CCPWM60A 60A 12/24V for Hydrogen Systems
The CCPWM60A (Constant Current Pulse Width Modulator) will allow you to have always the same amperage and HHO production regardless the electrolyte concentration or water temperature. This devise it will keep the amperage stable at a defined value independent of the electrolyte concentration, water temperature, water levels.
The CCPWM60A has been designed for making the automatic power supply of the HHO System without the need for relays or picking up the signal from the alternator/ignition key, making the system safer to use and easier to install.
The new CCPWM60A works based on the voltage of the car/truck:
- Engine stopped – voltage in car/truck 12V – PWM is not working;
- Engine working – voltage in car/truck 13,8V – PWM is working.
The CCPWM60A autodetect when the car engine is running and automatically switches ON the HHO System, without any additional requirements. The device will automatically power OFF when the car engine is turned OFF or not running.
The device is also capable to control a water level sensor inserted in the water tank turning the system OFF when the level drops from a certain point.
What are the main advantages?
Efficiency: HHO generators will run cooler than standard linear power amps, requiring substantially less heat sink mass;
Amperage control: The control of the amperage going into the generator will be very easy to be done. The ability to control the amperage keeps the cell running at cool operating temperatures and prolongs the life of the cell while increasing the H2 output.
Installation: It will make the HHO system easier and safer to install and use because there will be no need for relays or picking up the signal from the alternator/ignition key like in other pwms in the market.
Technical Specifications
- Direct connection from battery input to HHO CELL generator, without external relays
- 60A MAX HHO Cell power supply
- Dual LED meter: voltmeter + amperemeter, 5 to 40V, 60A
- Auto detect battery voltage and auto configuration for: +12/24V power supply
- Quad operational chip sensor with 1% tolerance Zenner voltage detector
- Auto power ON HHO Cell when the engine is running
- 1 Second delay PWM control, after engine ON is detected
- Auto Power OFF HHO Cell when engine is turned OFF
- Soft PWM startup to the max ampere out power supply
- Embedded trimmer for PWM control: 0 - 100% HHO Cell power supply
- Logical IC sensor
- Embedded 3 way power barrier: Positive, Gnd, CELL - OUT
- Optional water tank sensor switch embedded on system
- Compact blue ABS casing
- Dimensions: 100X50X40 mm
1-year Warranty
Made in European Union
Technical Specifications
-
ManualsManual PWM CCPWM60A 60A 12/24V
-
ManufacturerHHO Plus
Product Description
Constant Current Pulse Width Modulator PWM CCPWM60A 60A 12/24V for Hydrogen Systems
The CCPWM60A (Constant Current Pulse Width Modulator) will allow you to have always the same amperage and HHO production regardless the electrolyte concentration or water temperature. This devise it will keep the amperage stable at a defined value independent of the electrolyte concentration, water temperature, water levels.
The CCPWM60A has been designed for making the automatic power supply of the HHO System without the need for relays or picking up the signal from the alternator/ignition key, making the system safer to use and easier to install.
The new CCPWM60A works based on the voltage of the car/truck:
- Engine stopped – voltage in car/truck 12V – PWM is not working;
- Engine working – voltage in car/truck 13,8V – PWM is working.
The CCPWM60A autodetect when the car engine is running and automatically switches ON the HHO System, without any additional requirements. The device will automatically power OFF when the car engine is turned OFF or not running.
The device is also capable to control a water level sensor inserted in the water tank turning the system OFF when the level drops from a certain point.
What are the main advantages?
Efficiency: HHO generators will run cooler than standard linear power amps, requiring substantially less heat sink mass;
Amperage control: The control of the amperage going into the generator will be very easy to be done. The ability to control the amperage keeps the cell running at cool operating temperatures and prolongs the life of the cell while increasing the H2 output.
Installation: It will make the HHO system easier and safer to install and use because there will be no need for relays or picking up the signal from the alternator/ignition key like in other pwms in the market.
Technical Specifications
- Direct connection from battery input to HHO CELL generator, without external relays
- 60A MAX HHO Cell power supply
- Dual LED meter: voltmeter + amperemeter, 5 to 40V, 60A
- Auto detect battery voltage and auto configuration for: +12/24V power supply
- Quad operational chip sensor with 1% tolerance Zenner voltage detector
- Auto power ON HHO Cell when the engine is running
- 1 Second delay PWM control, after engine ON is detected
- Auto Power OFF HHO Cell when engine is turned OFF
- Soft PWM startup to the max ampere out power supply
- Embedded trimmer for PWM control: 0 - 100% HHO Cell power supply
- Logical IC sensor
- Embedded 3 way power barrier: Positive, Gnd, CELL - OUT
- Optional water tank sensor switch embedded on system
- Compact blue ABS casing
- Dimensions: 100X50X40 mm
1-year Warranty
Made in European Union
Technical Specifications
-
ManualsManual PWM CCPWM60A 60A 12/24V
-
ManufacturerHHO Plus